Advanced Power System Analysis In Electrical Networks Using ETAP Power Station
Course Description
Power systems equipment must withstand not only the rated voltage, which corresponds to the highest voltage of a particular system, but also expected short level. Accordingly, it is necessary to set protective relays based on these results obtained from short circuit study. One of hot issues now related to these is arc flashing study which is mainly based on the studies of short circuit and relay co-ordination as well. All these three issues should be dealt as integral parts & bulk. Power System Analysis means verifying the adequacy of the power distribution system and its components recognize coordination related disturbances and outages and collecting the required data to perform a detailed required study. The continuity and quality of electricity delivered safely and economically by todays and futures electrical power networks are important for both developed and developing economies. The correct modeling of power system equipment and correct fault analysis of electrical networks are pre-requisite to ensuring safety and they play a critical role in the identification of economic network investments. Environmental and economic factors require engineers to maximize the use of existing assets which in turn require accurate modeling and analysis techniques.
The Training Course Will Highlight ?
Training Objective

On successful completion of this course, participants will be able to:

  • Understand importance of power system modeling
  • Understand the need for calculation the short circuit current.
  • Consequences of sustained fault current & type if faults.
  • Manual calculation of short circuit using simple methods like MVA method, P.U. system, etc…
  • Balanced & unbalanced power flow analysis.
  • Voltage drop
  • Analyze the motor starting/acceleration.
  • Switchgear rating (breaking & making capacities).
  • Power problem problems & assessment.
  • Importance of arc flashing and relay co-ordination studies from operation & safety point of view.
  • Test cases simulation using computer software’s.

Target Audience

This course is intended for anyone who must perform calculations, provide settings or approve the work performed by others. The trainee should be a graduate engineer or have the equivalent practical work experience in electrical power systems. i.e.

  • Consulting Engineers.
  • Electrical Engineers.
  • Project Engineers.
  • Maintenance Engineers.
  • Commissioning & testing Engineers.

Training Methods

This interactive Training will be highly interactive, with opportunities to advance your opinions and ideas and will include;

  • Lectures
  • Workshop & Work Presentation
  • Case Studies and Practical Exercise
  • Videos and General Discussions

Daily Agenda

Day 1

  • Overview of ETAP Capabilities & Limitations.
  • One-Line Diagram/One line View (OLV).
  • Creating & Merging different revisions, presentations & configuration
  • Scenario, Study & Project Wizards.
  • Crystal Reports & Customizations.
  • AC & DC Element Descriptions.

 

Day 2

  • Load modeling.
  • Add, updating and remove from ETAP library.
  • Electrical systems modeling and fundamentals.
  • Load flow (balanced & unbalanced) analysis.
  • Load Flow & Cable sizing.
  • Transformer sizing.
  • Benefits of calculated short circuit currents.

 

Day 3

  • Introduction to Fault current Calculations in brief.
  • Breaking & making currents.
  • Per unit systems.
  • Different typical values of positive, negative & zero phase sequence impedances for unbalance faults.
  • Manual Calculations of Isc by MVA Method.
  • Calculation of Isc by Impedance method.

 

Day 4

  • Calculation of Isc by symmetrical components.
  • Calculations as defined & recommended by IEC/ANSI standards.
  • Short Circuit Studies (Fault-Levels – Switchgear/Fuse Rating). Typical cases for switchgear sizing.
  • Relay co-ordination & Arc Flashing studies.
  • Coordination Fundamentals
  • Procedures
  • Data Collection
  • Plotting Time/Current Curves
  • Relay Coordination Intervals

 

Day 5

  • Equipment’s damage curves for cables, transformers, etc...
  • System Modeling for Device Coordination Study
  • ETAP Star (Device Co-ordination/selectivity).
  • System earthling (Solid, resistance & reactance or even ungrounded systems)
  • Substation grounding grid design & Calculations.
  • Motor Parameter Estimation.
  • Motor Acceleration Analysis (Dynamic & Static).
  • Different test simulation cases using ETAP power station version 7.00.
Accreditation

BTS attendance certificate will be issued to all attendees completing a minimum of 80% of the total course duration.

Quick Enquiry

Request Info

Download Brochure Request In house Proposal

Course Rounds : (5 -Days)


Code Date Venue Fees Register
EE186-01 03-06-2024 Kuala-Lumpur USD 5950
EE186-02 11-08-2024 Dubai USD 5450
EE186-03 13-10-2024 Riyadh USD 5450
EE186-04 15-12-2024 Dubai USD 5450
Prices doesn't include VAT

UpComing Date


Details
  • Start date 03-06-2024
  • End date 07-06-2024

Venue
  • Country Malaysia
  • Venue Kuala-Lumpur

Quality Policy

 Providing services with a high quality that are satisfying the requirements
 Appling the specifications and legalizations to ensure the quality of service.
 Best utilization of resources for continually improving the business activities.

Technical Team

BTS keen to selects highly technical instructors based on professional field experience

Strengths and capabilities

Since BTS was established, it considered a training partner for world class oil & gas institution

Search For Available Course

Abu Dhabi, UAE

1st floor, Incubator Buildingو Masdar City, Abu Dhabi, UAE

00971-2-6446633

Sun to Fri 09:00 AM to 06:00 PM

info@btsconsultant.com

Contact Us anytime!